S2I Conversion Settings List and Convert Button

Conversion Settings List:

This list contains all of the defined conversion settings.

Convert to INM Button:

Clicking this button immediately converts the SIMMOD scenarios included within the selected conversion setting into INM data. If the INM directory is not set, S2I requests a directory. Once completed, S2I pops up a 'done processing' message.

This button is disabled when there are no included SIMMOD scenarios, when some of the required user options on the Settings Tab are not set, or if some other environmental problem occurs to prevent a successful data conversion.

Should a runway identifier not be mapped or a SIMMOD model appears which is not mapped, then the SIMMOD to INM conversion stops with an error.

As SIMMOD scenarios can contain large amounts of data, it is recommended that this feature be used on smaller data sets to verify the user settings for the chosen conversion setting. Converting moderate to large SIMMOD studies may take too long for interactive use.